{"product_id":"true-north-tn25c-wood-stove","title":"True North TN25c Wood Stove With Legs","description":"\u003cp data-start=\"264\" data-end=\"761\" class=\"PDq2pG_selectionAnchorContainer\"\u003eThe \u003cstrong data-start=\"268\" data-end=\"299\"\u003eTrue North TN25c Wood Stove\u003c\/strong\u003e is designed to deliver efficient wood heating with straightforward operation. The \u003cstrong data-start=\"382\" data-end=\"422\"\u003eTrue North TN25c Wood Stove 31010016\u003c\/strong\u003e combines Electronic Combustion Assist and Passive Catalytic Technology to support clean-burning performance without requiring a manual bypass, helping simplify everyday use. Its single lever air control makes adjusting the fire easy, while the air wash system helps keep the ceramic glass cleaner for improved visibility during operation.\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp data-start=\"763\" data-end=\"1379\"\u003eBuilt with a heavy plate-steel top and a cast iron door, this wood stove is designed for dependable performance and durability. The 2.0 cu. ft. firebox accommodates logs up to 18 inches long, providing flexibility when loading firewood. With an HHV efficiency rating of 76%, EPA heat output ranging from 13,900 to 29,200 BTU, and cord wood heat output up to 60,000 BTU, the stove is engineered to provide effective heating while maintaining low emissions of 1.1 g\/hr. The TN25c is EPA2020 Certified, supports both inside and outside combustion air, is mobile home approved, and is available with Metallic Black legs.\u003c\/p\u003e\n\u003ch3 data-section-id=\"161rloe\" data-start=\"1386\" data-end=\"1400\"\u003eFeatures\u003c\/h3\u003e\n\u003cul data-start=\"1402\" data-end=\"1799\"\u003e\n\u003cli data-section-id=\"ax4olv\" data-start=\"1402\" data-end=\"1432\"\u003eEPA2020 Certified wood stove\u003c\/li\u003e\n\u003cli data-section-id=\"1spke2g\" data-start=\"1433\" data-end=\"1480\"\u003eElectronic Combustion Assist (Patent Pending)\u003c\/li\u003e\n\u003cli data-section-id=\"1td6nb1\" data-start=\"1481\" data-end=\"1528\"\u003ePassive Catalytic Technology (Patent Pending)\u003c\/li\u003e\n\u003cli data-section-id=\"lf81g0\" data-start=\"1529\" data-end=\"1556\"\u003eNo manual bypass required\u003c\/li\u003e\n\u003cli data-section-id=\"tiqh2f\" data-start=\"1557\" data-end=\"1604\"\u003eSingle lever air control for simple operation\u003c\/li\u003e\n\u003cli data-section-id=\"1gby2sr\" data-start=\"1605\" data-end=\"1659\"\u003eAir wash system helps maintain cleaner ceramic glass\u003c\/li\u003e\n\u003cli data-section-id=\"18zpo2p\" data-start=\"1660\" data-end=\"1703\"\u003eHeavy plate-steel top with cast iron door\u003c\/li\u003e\n\u003cli data-section-id=\"107vf05\" data-start=\"1704\" data-end=\"1748\"\u003eSupports inside and outside combustion air\u003c\/li\u003e\n\u003cli data-section-id=\"uwgrnw\" data-start=\"1749\" data-end=\"1771\"\u003eMobile home approved\u003c\/li\u003e\n\u003cli data-section-id=\"1kle9hx\" data-start=\"1772\" data-end=\"1799\"\u003eMetallic Black leg option\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"yupr4m\" data-start=\"1806\" data-end=\"1826\"\u003eSpecifications\u003c\/h3\u003e\n\u003cdiv class=\"TyagGW_tableContainer\"\u003e\n\u003cdiv class=\"group TyagGW_tableWrapper flex flex-col-reverse w-fit\" tabindex=\"-1\"\u003e\n\u003ctable data-start=\"1828\" data-end=\"2750\" class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead data-start=\"1828\" data-end=\"1855\"\u003e\n\u003ctr data-start=\"1828\" data-end=\"1855\"\u003e\n\u003cth data-start=\"1828\" data-end=\"1844\" data-col-size=\"sm\" class=\"last:pe-10\"\u003eSpecification\u003c\/th\u003e\n\u003cth data-start=\"1844\" data-end=\"1855\" data-col-size=\"md\" class=\"last:pe-10\"\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody data-start=\"1883\" data-end=\"2750\"\u003e\n\u003ctr data-start=\"1883\" data-end=\"1905\"\u003e\n\u003ctd data-start=\"1883\" data-end=\"1891\" data-col-size=\"sm\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-start=\"1891\" data-end=\"1905\" data-col-size=\"md\"\u003eTrue North\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1906\" data-end=\"1951\"\u003e\n\u003ctd data-start=\"1906\" data-end=\"1921\" data-col-size=\"sm\"\u003eProduct Name\u003c\/td\u003e\n\u003ctd data-start=\"1921\" data-end=\"1951\" data-col-size=\"md\"\u003eTN25c Wood Stove With Legs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1952\" data-end=\"1970\"\u003e\n\u003ctd data-start=\"1952\" data-end=\"1958\" data-col-size=\"sm\"\u003eSKU\u003c\/td\u003e\n\u003ctd data-start=\"1958\" data-end=\"1970\" data-col-size=\"md\"\u003e31010016\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1971\" data-end=\"1988\"\u003e\n\u003ctd data-start=\"1971\" data-end=\"1979\" data-col-size=\"sm\"\u003eModel\u003c\/td\u003e\n\u003ctd data-start=\"1979\" data-end=\"1988\" data-col-size=\"md\"\u003eTN25c\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"1989\" data-end=\"2018\"\u003e\n\u003ctd data-start=\"1989\" data-end=\"2004\" data-col-size=\"sm\"\u003eProduct Type\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2004\" data-end=\"2018\"\u003eWood Stove\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2019\" data-end=\"2043\"\u003e\n\u003ctd data-start=\"2019\" data-end=\"2036\" data-col-size=\"sm\"\u003eHHV Efficiency\u003c\/td\u003e\n\u003ctd data-start=\"2036\" data-end=\"2043\" data-col-size=\"md\"\u003e76%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2044\" data-end=\"2082\"\u003e\n\u003ctd data-start=\"2044\" data-end=\"2068\" data-col-size=\"sm\"\u003eCord Wood Heat Output\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2068\" data-end=\"2082\"\u003e60,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2083\" data-end=\"2122\"\u003e\n\u003ctd data-start=\"2083\" data-end=\"2101\" data-col-size=\"sm\"\u003eEPA Heat Output\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2101\" data-end=\"2122\"\u003e13,900–29,200 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2123\" data-end=\"2147\"\u003e\n\u003ctd data-start=\"2123\" data-end=\"2135\" data-col-size=\"sm\"\u003eEmissions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2135\" data-end=\"2147\"\u003e1.1 g\/hr\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2148\" data-end=\"2182\"\u003e\n\u003ctd data-start=\"2148\" data-end=\"2167\" data-col-size=\"sm\"\u003eFirebox Capacity\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2167\" data-end=\"2182\"\u003e2.0 cu. ft.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2183\" data-end=\"2214\"\u003e\n\u003ctd data-start=\"2183\" data-end=\"2204\" data-col-size=\"sm\"\u003eMaximum Log Length\u003c\/td\u003e\n\u003ctd data-start=\"2204\" data-end=\"2214\" data-col-size=\"md\"\u003e18 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2215\" data-end=\"2257\"\u003e\n\u003ctd data-start=\"2215\" data-end=\"2229\" data-col-size=\"sm\"\u003eAir Control\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2229\" data-end=\"2257\"\u003eSingle Lever Air Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2258\" data-end=\"2331\"\u003e\n\u003ctd data-start=\"2258\" data-end=\"2282\" data-col-size=\"sm\"\u003eCombustion Technology\u003c\/td\u003e\n\u003ctd data-start=\"2282\" data-end=\"2331\" data-col-size=\"md\"\u003eElectronic Combustion Assist (Patent Pending)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2332\" data-end=\"2404\"\u003e\n\u003ctd data-start=\"2332\" data-end=\"2355\" data-col-size=\"sm\"\u003eCatalytic Technology\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2355\" data-end=\"2404\"\u003ePassive Catalytic Technology (Patent Pending)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2405\" data-end=\"2437\"\u003e\n\u003ctd data-start=\"2405\" data-end=\"2421\" data-col-size=\"sm\"\u003eManual Bypass\u003c\/td\u003e\n\u003ctd data-start=\"2421\" data-end=\"2437\" data-col-size=\"md\"\u003eNot Required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2438\" data-end=\"2472\"\u003e\n\u003ctd data-start=\"2438\" data-end=\"2453\" data-col-size=\"sm\"\u003eGlass System\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2453\" data-end=\"2472\"\u003eAir Wash System\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2473\" data-end=\"2524\"\u003e\n\u003ctd data-start=\"2473\" data-end=\"2490\" data-col-size=\"sm\"\u003eCombustion Air\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2490\" data-end=\"2524\"\u003eInside and Outside Air Capable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2525\" data-end=\"2565\"\u003e\n\u003ctd data-start=\"2525\" data-end=\"2540\" data-col-size=\"sm\"\u003eConstruction\u003c\/td\u003e\n\u003ctd data-start=\"2540\" data-end=\"2565\" data-col-size=\"md\"\u003eHeavy Plate-Steel Top\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2566\" data-end=\"2595\"\u003e\n\u003ctd data-start=\"2566\" data-end=\"2582\" data-col-size=\"sm\"\u003eDoor Material\u003c\/td\u003e\n\u003ctd data-start=\"2582\" data-end=\"2595\" data-col-size=\"md\"\u003eCast Iron\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2596\" data-end=\"2626\"\u003e\n\u003ctd data-start=\"2596\" data-end=\"2619\" data-col-size=\"sm\"\u003eMobile Home Approved\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2619\" data-end=\"2626\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2627\" data-end=\"2666\"\u003e\n\u003ctd data-start=\"2627\" data-end=\"2643\" data-col-size=\"sm\"\u003eFinish Option\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2643\" data-end=\"2666\"\u003eMetallic Black Legs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2667\" data-end=\"2696\"\u003e\n\u003ctd data-start=\"2667\" data-end=\"2680\" data-col-size=\"sm\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2680\" data-end=\"2696\"\u003eNot Provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2697\" data-end=\"2722\"\u003e\n\u003ctd data-start=\"2697\" data-end=\"2706\" data-col-size=\"sm\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2706\" data-end=\"2722\"\u003eNot Provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-start=\"2723\" data-end=\"2750\"\u003e\n\u003ctd data-start=\"2723\" data-end=\"2734\" data-col-size=\"sm\"\u003eWarranty\u003c\/td\u003e\n\u003ctd data-col-size=\"md\" data-start=\"2734\" data-end=\"2750\"\u003eNot Provided\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3 data-section-id=\"fncqjj\" data-start=\"2757\" data-end=\"2792\"\u003eTechnical Documents \u0026amp; Manuals\u003c\/h3\u003e\n\u003cul data-start=\"2794\" data-end=\"2986\"\u003e\n\u003cli data-section-id=\"pcxsb\" data-start=\"2794\" data-end=\"2854\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1007\/6622\/0420\/files\/true-north-tn25c-wood-stove-user-manual.pdf?v=1782996702\" target=\"_blank\" rel=\"noopener\"\u003eTrue North TN25c Wood Stove User Manual (PDF)\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3 data-section-id=\"jeg8xi\" data-start=\"3469\" data-end=\"3491\" class=\"PDq2pG_selectionAnchorContainer\"\u003eProduct FAQs\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp data-section-id=\"in0j1q\" data-start=\"3493\" data-end=\"3568\"\u003e\u003cstrong\u003eQ1. What is the maximum heat output of the True North TN25c Wood Stove?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3570\" data-end=\"3729\"\u003eThe True North TN25c Wood Stove delivers up to \u003cstrong data-start=\"3617\" data-end=\"3631\"\u003e60,000 BTU\u003c\/strong\u003e heat output when using cord wood. The EPA-rated heat output ranges from \u003cstrong data-start=\"3704\" data-end=\"3728\"\u003e13,900 to 29,200 BTU\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-section-id=\"1skb58y\" data-start=\"3731\" data-end=\"3778\"\u003e\u003cstrong\u003eQ2. Does the TN25c require a manual bypass?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3780\" data-end=\"3931\"\u003eNo. The TN25c uses \u003cstrong data-start=\"3799\" data-end=\"3831\"\u003eElectronic Combustion Assist\u003c\/strong\u003e together with \u003cstrong data-start=\"3846\" data-end=\"3878\"\u003ePassive Catalytic Technology\u003c\/strong\u003e, allowing it to operate \u003cstrong data-start=\"3903\" data-end=\"3930\"\u003ewithout a manual bypass\u003c\/strong\u003e.\u003c\/p\u003e\n\u003cp data-section-id=\"xhn20f\" data-start=\"3933\" data-end=\"3986\"\u003e\u003cstrong\u003eQ3. What size firewood can the TN25c accommodate?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp data-start=\"3988\" data-end=\"4218\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eThe TN25c features a \u003cstrong data-start=\"4009\" data-end=\"4032\"\u003e2.0 cu. ft. firebox\u003c\/strong\u003e and accepts logs up to \u003cstrong data-start=\"4056\" data-end=\"4069\"\u003e18 inches\u003c\/strong\u003e in length. It also includes a cast iron door, heavy plate-steel top, and an air wash system to help keep the ceramic glass cleaner during operation.\u003c\/p\u003e","brand":"True North","offers":[{"title":"Default Title","offer_id":52436790116484,"sku":"31010016","price":3081.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1007\/6622\/0420\/files\/true-north-tn25c-wood-stove.jpg?v=1782996887","url":"https:\/\/indoorstoves.com\/products\/true-north-tn25c-wood-stove","provider":"Indoor Stoves","version":"1.0","type":"link"}